Answering now · 24 hours, 7 days

Smell gas? Leave the house, then call 911 or your gas utility.

(864) 415-7482
Gas Guys Plumbing & Heating

Gas Appliance Hookups

Pool and Spa Heater Gas Lines in Spartanburg, SC

The biggest gas appliance most homes will ever have, fed by a line sized to carry it.

Call (864) 415-7482 Request service

  • Real people answering 24/7
  • Transparent, up-front pricing
  • Fully licensed & insured in SC & NC

A gas pool heater is not a grill. Residential pool and spa heaters commonly carry ratings from about 250,000 to 400,000 BTU an hour, which is more than a furnace, a tank water heater, a range and a dryer added together in a typical Upstate house. Feeding one is a different job from tapping a line for a patio burner.

The heater also tends to sit at the far end of the yard. The equipment pad is wherever the pool builder put the pump and filter, often behind a fence or beside the deep end, and that can be well over a hundred feet from the gas meter. Long distance plus big load is exactly the combination that makes pipe size critical.

Get the line wrong and the heater will tell you. It lights, runs for a minute, then locks out on a flame or pressure fault, or it simply cannot hold temperature in the spa on a cool evening. Nothing is leaking. The pipe just cannot move enough gas that far.

We plan the line around the heater's data plate and the rest of the house, confirm the meter can carry it, trench and run the pipe to the pad, test it, get it inspected, and check the pressure at the heater while it is firing at full rate.

  • Piedmont Natural Gas Advantage Partner

Your pool heater line may be the problem if

  • The heater lights and then shuts down with a flame failure or low gas pressure code
  • The spa takes hours longer to heat than the heater's rating suggests it should
  • The heater runs fine alone but faults when the furnace or water heater is also running
  • Other gas appliances in the house flicker or lose flame while the pool heater fires
  • You are replacing an older, smaller heater with a higher-BTU model on the same line
  • You are adding a spa, a heated pool or a heater to an existing pool for the first time

Heaters and equipment we feed

  • Gas pool heaters for in-ground pools
  • Spa and hot tub heaters
  • Combination pool and spa systems with one heater
  • Replacement heaters with a higher BTU rating than the old one
  • Swim spas and plunge pools with gas heat
  • Fire bowls and gas features on the pool deck, on the same run

Why BTUs drive everything on a pool heater job

Natural gas carries roughly 1,000 BTU per cubic foot. A 400,000 BTU heater running at full fire therefore burns about 400 cubic feet of gas an hour. For comparison, a typical tank water heater burns around 40, and a furnace somewhere between 60 and 100. The pool heater is the elephant on the line.

Pipe sizing in the fuel gas code works from two numbers: the total flow the pipe has to carry and its developed length, meaning the full distance along the pipe, not as the crow flies. Double the length and the pipe has to get larger to deliver the same flow at the same pressure drop. A run that would be fine in three-quarter-inch for a grill can need one and a quarter inch or more for a big heater at the end of the yard.

The heater has a minimum inlet pressure printed in its installation manual. When it fires, our job is to make sure the pressure at its gas valve stays above that number, with everything else in the house running too. That is the test that matters, and we take the reading with the heater lit.

Can your meter carry a pool heater?

The utility sizes the meter and its regulator for the load it expected when the house was built. A house with a furnace, water heater and range might have a meter that was never meant to pass an extra 300 or 400 cubic feet an hour. Add a pool heater and the meter itself can become the bottleneck, no matter how big the pipe after it is.

We add up the connected load before any digging starts. If the total looks beyond what the meter is likely to deliver, the utility has to review it and may need to swap the meter or regulator. That is their equipment and their schedule, so we raise it at the start of the project, not the week the pool is filled.

In some cases the better answer is an elevated-pressure line to the pad, where the utility delivers gas at 2 psi and a regulator at the heater drops it to appliance pressure. Higher pressure moves more gas through smaller pipe, which can make a long run practical. It needs the utility's agreement, and the regulator has to be one rated for outdoor use and installed where it can be reached.

Getting the line out to the equipment pad

Most pool heater lines leave the house above ground in steel, drop into the yard and run underground in polyethylene to the pad, then rise back out of the ground in steel at the heater. Plastic gas pipe is never run above ground. It gets a tracer wire alongside so it can be found with a locator later, and the transition fittings at each end are listed for the purpose.

Trenching in a finished backyard takes planning. Irrigation lines, landscape lighting, pool plumbing and the pool's bonding grid are all in the way, and none of those are marked by SC811 because they belong to you. We locate what we can, ask what you know, and route around the pool shell and deck.

At the heater the line ends in an accessible shutoff valve and a sediment trap before the appliance connector, the same as any gas appliance. The heater manufacturer also sets clearances from windows, doors, air intakes and overhangs, so the location the pool builder picked sometimes has to move a few feet.

New pool or replacement heater

On a new pool, the gas line is one trade among several, and the timing matters. The best time to trench is before the deck is poured and the yard is sodded. We coordinate with the pool builder on where the pad goes and when the trench can be open, and the underground pipe gets its pressure test and inspection before the trench is backfilled.

On a replacement, the question is whether the existing line was ever sized properly. Many older pools had a smaller heater, and many lines were run by whoever was on site at the time. Swapping a 250,000 BTU heater for a 400,000 BTU model on the same pipe is the most common way to end up with a new heater that keeps faulting. We check the existing pipe size and length against the new heater before you order it.

How a pool heater gas line goes in

  1. Read the heater and add up the house

    We take the heater's BTU rating and minimum inlet pressure from its data plate or manual, then add every other gas appliance on the meter.

  2. Check the meter and plan the route

    If the total load looks larger than the meter is likely to deliver, we bring the utility in early. Then we measure the developed length to the pad and size the pipe from the code tables.

  3. Permit

    New gas piping needs a permit from the city or county building office that covers your address. We file it.

  4. Trench and run the line

    Steel above ground, polyethylene with tracer wire below, listed transitions at each end, and a shutoff and sediment trap at the heater.

  5. Test and inspect before backfill

    The new piping is pressure-tested and held on a gauge, and the inspector sees the underground work before the trench is closed.

  6. Fire the heater and measure

    With the heater at full fire and other appliances running, we read the inlet pressure at the heater to confirm it stays above the manufacturer's minimum.

Not sure this is the problem? Describe what is happening and we will tell you.

(864) 415-7482

Permits for pool heater gas lines

A gas line to a pool heater is new gas piping, and it needs a permit and inspection like any other. Inside a city the city building department handles it; outside city limits it is the county. In unincorporated Spartanburg County, underground gas piping is inspected with its pressure test before the trench is backfilled, so the timing of the dig and the inspection are linked.

The pool, its electrical bonding and the heater's wiring are separate permits held by the pool builder and the electrician. We handle the gas piping permit and work around theirs.

What drives the cost of a pool heater line

Every job is priced before work starts. These are the things that move the number.

Distance to the pad
The developed length from the meter or tie-in point to the heater is the single biggest factor, both for labor and for the pipe size it forces.
Heater size
A 400,000 BTU heater needs a much larger pipe than a 250,000 BTU unit over the same distance.
Meter and pressure
If the utility has to upgrade the meter or approve an elevated-pressure system, that adds steps and a regulator at the pad.
What is in the yard
Hardscape, mature trees, irrigation and a finished deck all slow the trench. An open yard during pool construction is the fastest case.
Existing pipe
On a replacement, reusing a properly sized line is simple. Undersized pipe means replacing some or all of it.
Permit and inspection
Fees are set by the city or county and apply to every job.

Who supplies gas in your town

Your utility owns the main and the meter and handles gas emergencies at the meter. Everything after the meter is yours, and that is the piping we install and repair.

TownNatural gasPermits
Spartanburg Piedmont Natural Gas City of Spartanburg Building Inspections; Spartanburg County Building Codes outside city limits
Boiling Springs Piedmont Natural Gas Spartanburg County Building Codes
Inman Piedmont Natural Gas City of Inman (processed by SAFEbuilt)
Chesnee Piedmont Natural Gas or propane Cherokee County Building Safety, after City of Chesnee zoning approval
Cowpens Piedmont Natural Gas Town of Cowpens (building safety by CC&I Services)
Gaffney Piedmont Natural Gas City of Gaffney Community Development; Cherokee County Building Safety outside city limits
Duncan Greer CPW Town of Duncan
Wellford Greer CPW City of Wellford
Lyman Greer CPW Town of Lyman zoning approval, then CC&I Services
Moore Varies: Piedmont, Greer CPW or propane Spartanburg County Building Codes
Woodruff Piedmont Natural Gas City of Woodruff Building Department
Landrum Greer CPW City of Landrum (start at City Hall); Spartanburg County Building Codes outside city limits
Campobello Mostly propane (no gas main confirmed) Spartanburg County Building Codes (confirm with Campobello Town Hall)
Roebuck Piedmont Natural Gas Spartanburg County Building Codes
Pacolet City of Union (Union Gas) Town of Pacolet, through its contracted building inspection firm
Converse Piedmont Natural Gas Spartanburg County Building Codes
Fairforest Piedmont Natural Gas Spartanburg County Building Codes
Startex Greer CPW or Piedmont (check your bill) Spartanburg County Building Codes
Reidville Greer CPW Town of Reidville (zoning approval, then CC&I for permits); Spartanburg County outside town limits
Arcadia Piedmont Natural Gas Spartanburg County Building Codes
Clifton Piedmont Natural Gas Spartanburg County Building Codes
Drayton Piedmont Natural Gas Spartanburg County Building Codes
Fingerville Propane in most homes; check for Piedmont service Spartanburg County Building Codes
Glendale Piedmont Natural Gas (where mains reach) Spartanburg County Building Codes
Gramling Varies: propane or natural gas, by road Spartanburg County Building Codes
Greer Greer CPW City of Greer Building and Development Standards (inside city limits)
Holly Springs Varies: Greer CPW, Piedmont or propane Spartanburg County Building Codes
Mayo Varies: Piedmont where mains run, propane elsewhere Spartanburg County Building Codes
Pacolet Mills City of Union (Union Gas); confirm on your bill Town of Pacolet, through its contracted building inspection firm
Pauline Varies: Piedmont where mains run, propane elsewhere Spartanburg County Building Codes
Southern Shops Piedmont Natural Gas Spartanburg County Building Codes
Una Piedmont Natural Gas Spartanburg County Building Codes
Whitestone Varies: Piedmont where mains run, propane elsewhere Spartanburg County Building Codes
Chimney Rock Propane (no gas main) Rutherford County Building Inspections (village zoning permit first)
Lake Lure Propane (no gas main) Rutherford County Building Inspections (Town of Lake Lure zoning permit first)
Forest City Enbridge Gas North Carolina Town of Forest City Building Inspections
Rutherfordton Enbridge Gas North Carolina Rutherford County Building Inspections (town zoning permit first for additions)
Spindale Enbridge Gas North Carolina Rutherford County Building Inspections (town zoning permit first for additions)
Union Mills Mostly propane Rutherford County Building Inspections
Mill Spring Enbridge Gas North Carolina (limited); propane elsewhere Polk County Building Inspections
Tryon Enbridge Gas North Carolina Polk County Building Inspections (Town of Tryon zoning permit first)
Columbus Enbridge Gas North Carolina Polk County Building Inspections (Town of Columbus zoning permit first)
Green Creek Mostly propane Polk County Building Inspections

Utility territories have edges, and rural homes past the mains run on propane. Check your bill if you are unsure.

Why pool owners call Gas Guys for the gas side

We do the math first

Load, length, meter and inlet pressure are checked before a shovel goes in the ground, not after a new heater starts faulting.

Gas is our trade

The pool builder handles the pool. We handle the part of the job that has to hold pressure and pass a gas inspection.

Measured under load

We do not stop at a lit burner. We read the pressure at the heater at full fire with the house running.

Buried lines you can find later

Tracer wire on every plastic run, and we show you where the line goes so the next project does not hit it.

Reviews

What customers say about our gas work

5.0 from 131 Google reviews

Jake did a great job of getting my gas powered fireplace back operational. Previously, I was informed from another company’s service technician that I needed to replace the fireplace unit, which would cost thousands of dollars. Jack took care of the problem within a short period of time! Thanks again Jake!!

Eric M. · Google · February 2026

I can’t say enough good things about The Gas Guy! Jake came out right away to hook up my sauna and did an amazing job. I’m apprehensive about anything gas - and it’s not everyday a gas heater for a sauna get installed. He was knowledgeable, professional, and explained everything clearly. Talk about peace of mind! On top of that, his pricing was very fair. It was a breath of fresh air to find someone reliable and skilled and just a nice guy. I would absolutely recommend him to anyone needing gas work done. Thank you again!

Stephanie B. · Google · 2025

These guys are great to work with. They are very professional, they know their gas codes, Their pricing is reasonable and fair. These guys are perfect for any of your Natural Gas needs. They care about their customers and are just good, hardworking guys.

Charles K. · Google · February 2026

More reviews Read them all on Google

Questions

Pool and Spa Heater Gas Lines: common questions

Still not sure? Call (864) 415-7482. A person answers 24/7. Or browse every common question.

How many BTUs is a gas pool heater?

Most residential gas pool and spa heaters fall between about 250,000 and 400,000 BTU an hour. That is usually more than every other gas appliance in the house combined, which is why the line and the meter both have to be checked.

What size gas line does a pool heater need?

It depends on the heater's BTU rating, the distance from the meter and the gas pressure available. Short runs to smaller heaters may be one inch; long runs to large heaters often need one and a quarter inch or more, or an elevated-pressure system. We size it from the fuel gas code tables for your actual run.

Why does my new pool heater keep shutting off?

A common cause is low gas pressure at the heater when it fires, especially after replacing a smaller heater on the same line. The heater sees the pressure drop and locks out for safety. We test the inlet pressure while it runs to tell a supply problem from a heater problem.

Will my gas meter handle a pool heater?

Not always. A meter sized for a furnace, water heater and range may not pass the extra gas a big heater uses. We add up the load and, if it is close, bring in the utility to review the meter before the heater goes in.

Does the gas line to the pool have to be buried?

The yard portion is normally run underground in polyethylene gas pipe with a tracer wire, and it rises out of the ground in steel at each end. Plastic gas pipe is not allowed above ground. Burying it also keeps it out of the way of mowers and foot traffic.

Can you run the line before the pool deck is poured?

That is the best time. We coordinate with your pool builder so the trench is open, tested and inspected before the deck and landscaping go in.

Do you repair pool heaters?

We handle the gas supply to the heater: the line, the valve, the pressure and the connection. Internal heater faults like a failed control board or heat exchanger are a job for the pool equipment service company, and our pressure readings help them rule the gas supply in or out.

24/7 · Spartanburg County & western NC

Need pool heater gas lines?

Call any hour, or send the details and a photo. You get the price before any work starts.

(864) 415-7482
  • Real people answering 24/7
  • Transparent, up-front pricing
  • Fully licensed & insured in SC & NC
  • Locally owned & operated
  • Financing available

Request service

Urgent? Call (864) 415-7482 instead.