A gas pool heater is not a grill. Residential pool and spa heaters commonly carry ratings from about 250,000 to 400,000 BTU an hour, which is more than a furnace, a tank water heater, a range and a dryer added together in a typical Upstate house. Feeding one is a different job from tapping a line for a patio burner.
The heater also tends to sit at the far end of the yard. The equipment pad is wherever the pool builder put the pump and filter, often behind a fence or beside the deep end, and that can be well over a hundred feet from the gas meter. Long distance plus big load is exactly the combination that makes pipe size critical.
Get the line wrong and the heater will tell you. It lights, runs for a minute, then locks out on a flame or pressure fault, or it simply cannot hold temperature in the spa on a cool evening. Nothing is leaking. The pipe just cannot move enough gas that far.
We plan the line around the heater's data plate and the rest of the house, confirm the meter can carry it, trench and run the pipe to the pad, test it, get it inspected, and check the pressure at the heater while it is firing at full rate.
- Piedmont Natural Gas Advantage Partner
Your pool heater line may be the problem if
- The heater lights and then shuts down with a flame failure or low gas pressure code
- The spa takes hours longer to heat than the heater's rating suggests it should
- The heater runs fine alone but faults when the furnace or water heater is also running
- Other gas appliances in the house flicker or lose flame while the pool heater fires
- You are replacing an older, smaller heater with a higher-BTU model on the same line
- You are adding a spa, a heated pool or a heater to an existing pool for the first time
Heaters and equipment we feed
- Gas pool heaters for in-ground pools
- Spa and hot tub heaters
- Combination pool and spa systems with one heater
- Replacement heaters with a higher BTU rating than the old one
- Swim spas and plunge pools with gas heat
- Fire bowls and gas features on the pool deck, on the same run
Why BTUs drive everything on a pool heater job
Natural gas carries roughly 1,000 BTU per cubic foot. A 400,000 BTU heater running at full fire therefore burns about 400 cubic feet of gas an hour. For comparison, a typical tank water heater burns around 40, and a furnace somewhere between 60 and 100. The pool heater is the elephant on the line.
Pipe sizing in the fuel gas code works from two numbers: the total flow the pipe has to carry and its developed length, meaning the full distance along the pipe, not as the crow flies. Double the length and the pipe has to get larger to deliver the same flow at the same pressure drop. A run that would be fine in three-quarter-inch for a grill can need one and a quarter inch or more for a big heater at the end of the yard.
The heater has a minimum inlet pressure printed in its installation manual. When it fires, our job is to make sure the pressure at its gas valve stays above that number, with everything else in the house running too. That is the test that matters, and we take the reading with the heater lit.
Can your meter carry a pool heater?
The utility sizes the meter and its regulator for the load it expected when the house was built. A house with a furnace, water heater and range might have a meter that was never meant to pass an extra 300 or 400 cubic feet an hour. Add a pool heater and the meter itself can become the bottleneck, no matter how big the pipe after it is.
We add up the connected load before any digging starts. If the total looks beyond what the meter is likely to deliver, the utility has to review it and may need to swap the meter or regulator. That is their equipment and their schedule, so we raise it at the start of the project, not the week the pool is filled.
In some cases the better answer is an elevated-pressure line to the pad, where the utility delivers gas at 2 psi and a regulator at the heater drops it to appliance pressure. Higher pressure moves more gas through smaller pipe, which can make a long run practical. It needs the utility's agreement, and the regulator has to be one rated for outdoor use and installed where it can be reached.
Getting the line out to the equipment pad
Most pool heater lines leave the house above ground in steel, drop into the yard and run underground in polyethylene to the pad, then rise back out of the ground in steel at the heater. Plastic gas pipe is never run above ground. It gets a tracer wire alongside so it can be found with a locator later, and the transition fittings at each end are listed for the purpose.
Trenching in a finished backyard takes planning. Irrigation lines, landscape lighting, pool plumbing and the pool's bonding grid are all in the way, and none of those are marked by SC811 because they belong to you. We locate what we can, ask what you know, and route around the pool shell and deck.
At the heater the line ends in an accessible shutoff valve and a sediment trap before the appliance connector, the same as any gas appliance. The heater manufacturer also sets clearances from windows, doors, air intakes and overhangs, so the location the pool builder picked sometimes has to move a few feet.
New pool or replacement heater
On a new pool, the gas line is one trade among several, and the timing matters. The best time to trench is before the deck is poured and the yard is sodded. We coordinate with the pool builder on where the pad goes and when the trench can be open, and the underground pipe gets its pressure test and inspection before the trench is backfilled.
On a replacement, the question is whether the existing line was ever sized properly. Many older pools had a smaller heater, and many lines were run by whoever was on site at the time. Swapping a 250,000 BTU heater for a 400,000 BTU model on the same pipe is the most common way to end up with a new heater that keeps faulting. We check the existing pipe size and length against the new heater before you order it.
How a pool heater gas line goes in
-
Read the heater and add up the house
We take the heater's BTU rating and minimum inlet pressure from its data plate or manual, then add every other gas appliance on the meter.
-
Check the meter and plan the route
If the total load looks larger than the meter is likely to deliver, we bring the utility in early. Then we measure the developed length to the pad and size the pipe from the code tables.
-
Permit
New gas piping needs a permit from the city or county building office that covers your address. We file it.
-
Trench and run the line
Steel above ground, polyethylene with tracer wire below, listed transitions at each end, and a shutoff and sediment trap at the heater.
-
Test and inspect before backfill
The new piping is pressure-tested and held on a gauge, and the inspector sees the underground work before the trench is closed.
-
Fire the heater and measure
With the heater at full fire and other appliances running, we read the inlet pressure at the heater to confirm it stays above the manufacturer's minimum.
Not sure this is the problem? Describe what is happening and we will tell you.
(864) 415-7482Permits for pool heater gas lines
A gas line to a pool heater is new gas piping, and it needs a permit and inspection like any other. Inside a city the city building department handles it; outside city limits it is the county. In unincorporated Spartanburg County, underground gas piping is inspected with its pressure test before the trench is backfilled, so the timing of the dig and the inspection are linked.
The pool, its electrical bonding and the heater's wiring are separate permits held by the pool builder and the electrician. We handle the gas piping permit and work around theirs.
What drives the cost of a pool heater line
Every job is priced before work starts. These are the things that move the number.
- Distance to the pad
- The developed length from the meter or tie-in point to the heater is the single biggest factor, both for labor and for the pipe size it forces.
- Heater size
- A 400,000 BTU heater needs a much larger pipe than a 250,000 BTU unit over the same distance.
- Meter and pressure
- If the utility has to upgrade the meter or approve an elevated-pressure system, that adds steps and a regulator at the pad.
- What is in the yard
- Hardscape, mature trees, irrigation and a finished deck all slow the trench. An open yard during pool construction is the fastest case.
- Existing pipe
- On a replacement, reusing a properly sized line is simple. Undersized pipe means replacing some or all of it.
- Permit and inspection
- Fees are set by the city or county and apply to every job.
Who supplies gas in your town
Your utility owns the main and the meter and handles gas emergencies at the meter. Everything after the meter is yours, and that is the piping we install and repair.
| Town | Natural gas | Permits |
|---|---|---|
| Spartanburg | Piedmont Natural Gas | City of Spartanburg Building Inspections; Spartanburg County Building Codes outside city limits |
| Boiling Springs | Piedmont Natural Gas | Spartanburg County Building Codes |
| Inman | Piedmont Natural Gas | City of Inman (processed by SAFEbuilt) |
| Chesnee | Piedmont Natural Gas or propane | Cherokee County Building Safety, after City of Chesnee zoning approval |
| Cowpens | Piedmont Natural Gas | Town of Cowpens (building safety by CC&I Services) |
| Gaffney | Piedmont Natural Gas | City of Gaffney Community Development; Cherokee County Building Safety outside city limits |
| Duncan | Greer CPW | Town of Duncan |
| Wellford | Greer CPW | City of Wellford |
| Lyman | Greer CPW | Town of Lyman zoning approval, then CC&I Services |
| Moore | Varies: Piedmont, Greer CPW or propane | Spartanburg County Building Codes |
| Woodruff | Piedmont Natural Gas | City of Woodruff Building Department |
| Landrum | Greer CPW | City of Landrum (start at City Hall); Spartanburg County Building Codes outside city limits |
| Campobello | Mostly propane (no gas main confirmed) | Spartanburg County Building Codes (confirm with Campobello Town Hall) |
| Roebuck | Piedmont Natural Gas | Spartanburg County Building Codes |
| Pacolet | City of Union (Union Gas) | Town of Pacolet, through its contracted building inspection firm |
| Converse | Piedmont Natural Gas | Spartanburg County Building Codes |
| Fairforest | Piedmont Natural Gas | Spartanburg County Building Codes |
| Startex | Greer CPW or Piedmont (check your bill) | Spartanburg County Building Codes |
| Reidville | Greer CPW | Town of Reidville (zoning approval, then CC&I for permits); Spartanburg County outside town limits |
| Arcadia | Piedmont Natural Gas | Spartanburg County Building Codes |
| Clifton | Piedmont Natural Gas | Spartanburg County Building Codes |
| Drayton | Piedmont Natural Gas | Spartanburg County Building Codes |
| Fingerville | Propane in most homes; check for Piedmont service | Spartanburg County Building Codes |
| Glendale | Piedmont Natural Gas (where mains reach) | Spartanburg County Building Codes |
| Gramling | Varies: propane or natural gas, by road | Spartanburg County Building Codes |
| Greer | Greer CPW | City of Greer Building and Development Standards (inside city limits) |
| Holly Springs | Varies: Greer CPW, Piedmont or propane | Spartanburg County Building Codes |
| Mayo | Varies: Piedmont where mains run, propane elsewhere | Spartanburg County Building Codes |
| Pacolet Mills | City of Union (Union Gas); confirm on your bill | Town of Pacolet, through its contracted building inspection firm |
| Pauline | Varies: Piedmont where mains run, propane elsewhere | Spartanburg County Building Codes |
| Southern Shops | Piedmont Natural Gas | Spartanburg County Building Codes |
| Una | Piedmont Natural Gas | Spartanburg County Building Codes |
| Whitestone | Varies: Piedmont where mains run, propane elsewhere | Spartanburg County Building Codes |
| Chimney Rock | Propane (no gas main) | Rutherford County Building Inspections (village zoning permit first) |
| Lake Lure | Propane (no gas main) | Rutherford County Building Inspections (Town of Lake Lure zoning permit first) |
| Forest City | Enbridge Gas North Carolina | Town of Forest City Building Inspections |
| Rutherfordton | Enbridge Gas North Carolina | Rutherford County Building Inspections (town zoning permit first for additions) |
| Spindale | Enbridge Gas North Carolina | Rutherford County Building Inspections (town zoning permit first for additions) |
| Union Mills | Mostly propane | Rutherford County Building Inspections |
| Mill Spring | Enbridge Gas North Carolina (limited); propane elsewhere | Polk County Building Inspections |
| Tryon | Enbridge Gas North Carolina | Polk County Building Inspections (Town of Tryon zoning permit first) |
| Columbus | Enbridge Gas North Carolina | Polk County Building Inspections (Town of Columbus zoning permit first) |
| Green Creek | Mostly propane | Polk County Building Inspections |
Utility territories have edges, and rural homes past the mains run on propane. Check your bill if you are unsure.
Why pool owners call Gas Guys for the gas side
We do the math first
Load, length, meter and inlet pressure are checked before a shovel goes in the ground, not after a new heater starts faulting.
Gas is our trade
The pool builder handles the pool. We handle the part of the job that has to hold pressure and pass a gas inspection.
Measured under load
We do not stop at a lit burner. We read the pressure at the heater at full fire with the house running.
Buried lines you can find later
Tracer wire on every plastic run, and we show you where the line goes so the next project does not hit it.