Gas logs sit unused from April to October, and then the first cold snap arrives and everybody turns the key at once. The pilot will not light, or it lights and goes out when you let go of the knob, or the burner comes on with a lazy orange flame and a smell nobody remembers from last year. Those are the calls we get every fall in Spartanburg.

Almost all of them come down to a short list of parts: a dirty pilot, a worn thermocouple or thermopile, a tripped oxygen depletion sensor on a vent-free set, a remote with dead batteries, or a gas valve that has been off all summer. They are fixable, usually in one visit, and most of the work is careful cleaning and testing rather than replacing things.

We also sell gas log sets, and we do the work that comes before the first fire: helping you choose a set that fits your fireplace, running a new gas line to a hearth that never had one, installing the shutoff valve, setting the logs, and checking an older set that came with the house. And we tell you plainly when an old set is not worth repairing.

Gas log set burning in a brick fireplace with glass doors, the technician in shoe covers beside the hearth
Gas logs lit and burning after service · a Gas Guys job · more job photos
  • Piedmont Natural Gas Advantage Partner

Call for gas log service if

  • The pilot will not light, or lights and goes out when you release the knob
  • The pilot stays lit but the main burner will not come on from the switch or remote
  • Your vent-free logs shut themselves off after running for a while
  • Flames are tall, orange and smoky, or black soot is building up on the logs or the firebox
  • You smell gas near the fireplace when the logs are off
  • Your carbon monoxide alarm sounds while the logs are running
  • The logs worked last winter and have not been lit since

What we sell, install and service

  • New vented and vent-free gas log sets, sized to your firebox
  • Vented gas log sets in masonry and factory-built fireplaces
  • Vent-free gas logs with oxygen depletion sensors
  • Standing pilot, millivolt and electronic ignition controls
  • Wall switches, thermostats and remote receivers
  • Direct-vent fireplace inserts (the gas side: supply, valve, burner and controls)
  • Gas starter pipes in wood-burning fireplaces
  • Key valves, floor valves and new gas lines to the hearth

Why gas logs will not light: the usual suspects

Most residential gas logs use a standing pilot. You push in the control knob, which lets gas flow to the pilot, and press the igniter to light it. The pilot flame then heats a small sensor. Until that sensor is hot enough, the gas valve will not hold itself open, which is why you have to hold the knob for 30 seconds or so before letting go.

If the pilot goes out the moment you let go, the sensor is not doing its job. On many sets that sensor is a thermocouple, a thin copper-colored rod that produces a tiny voltage when heated. Thermocouples wear out, get knocked out of the flame when logs are moved, and lose contact at the valve. Testing one takes a meter and a few minutes.

If the pilot stays lit but the burner will not come on from the wall switch or remote, look at the thermopile. It sits in the pilot flame too, but it generates enough power to run the valve and the switch circuit with no house electricity. A weak thermopile, a loose switch wire or a corroded terminal will leave you with a pilot and nothing else.

And if there is no pilot flame at all, the cause is usually gas not arriving: the key valve is off, the pilot orifice is clogged with dust or debris, or spiders have nested in the pilot tube over the summer. Spider webs in gas appliances are a real, common problem, and they are cleared with careful cleaning, not a coat hanger.

  • Pilot will not light: gas off, clogged pilot orifice, insects in the tube, failed igniter
  • Pilot lights, goes out on release: thermocouple, pilot flame too small, loose connection at the valve
  • Pilot stays lit, burner will not come on: thermopile, wall switch, remote receiver batteries, wiring
  • Vent-free logs shut off after a while: oxygen depletion sensor tripping, dirty ODS pilot, poor room air

Vented or vent-free: know which logs you have

Vented gas logs are decorative. They burn with tall, yellow flames that look like a wood fire, and their exhaust goes up the chimney. Because of that, the chimney damper must stay open whenever they are installed, and the fuel gas code requires the damper on a vented decorative set to be fixed open, usually with a clamp. Vented logs give off some heat, but most of it goes up the flue.

Vent-free logs are heaters. They burn hotter and cleaner with a mostly blue flame, and their exhaust stays in the room. That makes them very efficient, but it also means the moisture and combustion products they produce stay in the house with you. Every vent-free set has an oxygen depletion sensor, a precision pilot that shuts the gas off if the oxygen in the room starts to fall. Manufacturers limit vent-free logs to rooms of a minimum size and often limit run times, and the code restricts unvented heaters in bedrooms and bathrooms.

You can tell which you have from the rating label, usually on a chain or plate under the burner. The difference matters for service: log placement on a vent-free set is exact, because a log in the wrong spot interrupts the flame and makes soot and carbon monoxide. On either type, never add extra logs, rocks or decorative glass that did not come with the set.

The seasonal restart and cleaning

A yearly service before the first fire heads off most no-heat calls. We shut the gas off, pull the logs and grate, vacuum the burner and pan, and clean the pilot assembly and the ODS if there is one. We check the thermocouple or thermopile output with a meter, test the ignition, and inspect the flexible connector and valve for leaks.

Then we set the logs back in exactly the pattern the manufacturer shows, light the set, and watch the flame. Correct flame color and height depend on the logs being placed right and the burner ports being clear. On vented sets we confirm the damper is open and fixed. We also check that there is a working carbon monoxide alarm nearby, and we will tell you if there is not.

Sooty glass doors, logs that have crumbled or cracked, embers that have broken down to dust, and rusted burner pans are all things we look at and report. Some of that is cosmetic. Some of it changes how the set burns.

Choosing and buying a gas log set

We sell gas log sets, and the first question is not which logs look best. It is vented or vent-free. Vented sets give the tall, yellow flame of a wood fire and send their exhaust up the chimney, so they need a working flue and a damper fixed open. Vent-free sets are built to heat the room, burn with a mostly blue flame, and come with room-size and run-time limits. If you mainly want the look, vented is the usual answer. If you want heat in a room that gets cold, vent-free may be, as long as the room and the fireplace qualify.

Then the set has to fit the firebox. We measure the front width, back width, depth and height of your fireplace, because every burner and log set lists the minimum firebox it needs. A set that is too big crowds the flame into the logs and soots; one that is too small looks lost. Factory-built metal fireplaces add a rule of their own: a vent-free set can only go in one that is listed for vent-free use, which is on the fireplace's own label.

Last is the gas. If there is no line at the hearth, the set needs one, sized for its BTU rating with everything else on the meter, plus a shutoff valve you can reach. We tell you that before you buy, along with the fuel the set has to be built for, natural gas or propane, and the ignition type that suits how you will use it.

  • Vented or vent-free, based on whether you want the look or the heat
  • Burner and logs sized to your measured firebox
  • Listed for your fireplace type, masonry or factory-built
  • Built for your fuel, natural gas or propane
  • Standing pilot, millivolt with a wall switch or remote, or electronic ignition
  • A gas line and key valve at the hearth if there is not one

Installing gas logs where there were none

Plenty of older Upstate homes have a wood-burning masonry fireplace and no gas anywhere near it. Converting one to gas logs starts with a gas line: from the nearest suitably sized pipe, or a new branch from the meter, to the hearth, with a shutoff valve where you can reach it. The familiar key valve in the floor or wall beside the hearth is one way to do that, and it has to be accessible and identified.

The line is sized for the log set's BTU rating along with everything else on the meter, permitted, pressure-tested and inspected like any other new gas line. Before the logs go in, the chimney itself should be clean and sound, because a vented set depends on it to carry exhaust out. Chimney sweeping and masonry repair are their own trades, and we will tell you if we see a reason to call one.

For a fireplace insert, the venting is the insert installer's work and must follow the manufacturer's instructions exactly. We run the gas supply and valve to the insert, connect it, test it and service its burner and controls.

Carbon monoxide and gas logs

Any appliance that burns gas makes some carbon monoxide, and a properly adjusted one makes very little. Problems start when combustion goes wrong or exhaust has nowhere to go: a vented set with the damper closed, a blocked chimney, logs placed so they disturb the flame, or a vent-free set running in a small closed room for hours.

The basics are simple. Have a working carbon monoxide alarm on each level and outside sleeping areas. Never close the damper on vented logs. Follow the run-time and room-size limits on vent-free logs, and crack a window if the manufacturer calls for it. If the flame changes color or soot appears, stop using the set and have it looked at.

How a gas log service call goes

  1. Tell us what it is doing

    Will not light, goes out, burns dirty, shuts off, smells. The symptom points to the part, so a good description saves time.

  2. Shut off, cool down, inspect

    We turn off the gas at the valve, confirm the set is cool, and look at the logs, burner, pilot, valve and connector before touching anything.

  3. Test the controls

    We measure thermocouple or thermopile output, check the switch, remote and wiring, and check gas pressure where needed.

  4. Clean and repair

    The burner, pan, pilot and ODS are cleaned, and worn parts are replaced with ones that match the manufacturer and the gas type.

  5. Leak check and relight

    Every connection we touched is leak-checked, the logs go back in their correct positions, and we light the set and watch it run.

  6. Walk you through it

    We show you how to light it, where the shutoff is, and what a correct flame looks like, so you know when something has changed.

Not sure this is the problem? Describe what is happening and we will tell you.

(864) 415-7482

When gas log work needs a permit

Cleaning, restarts and like-for-like repairs on an existing set do not usually need a permit. Running a new gas line to a fireplace, or installing a gas appliance where there was none, is permitted work that gets a pressure test and an inspection from the city or county building office.

Replacing an old log set with a new one on the existing line is often treated as an appliance replacement. Requirements vary between the City of Spartanburg, unincorporated Spartanburg County and the other counties, so we check with the office that covers your address before the work starts.

What drives the cost of gas log work

Every job is priced before work starts. These are the things that move the number.

Repair or restart
A cleaning and relight is the simplest visit. A failed thermopile, valve or remote receiver adds parts.
Parts availability
Common thermocouples and pilot assemblies are easy to find. Parts for discontinued or unlabeled sets can be hard to source, and sometimes a new set is the better answer.
Type of control
Standing pilot, millivolt and electronic ignition systems differ in parts and diagnosis.
New gas line
A fireplace with no gas needs a line run from the meter or the nearest pipe, and the route to the hearth sets the effort.
Log set and burner
The size and type of set you choose, vented or vent-free, sets the BTU load and the line size.
Permit and inspection
Required for new lines and new installations; fees are set by the city or county.

Who supplies gas in your town

Your utility owns the main and the meter and handles gas emergencies at the meter. Everything after the meter is yours, and that is the piping we install and repair.

TownNatural gasPermits
Spartanburg Piedmont Natural Gas City of Spartanburg Building Inspections; Spartanburg County Building Codes outside city limits
Boiling Springs Piedmont Natural Gas Spartanburg County Building Codes
Inman Piedmont Natural Gas City of Inman (processed by SAFEbuilt)
Chesnee Piedmont Natural Gas or propane Cherokee County Building Safety, after City of Chesnee zoning approval
Cowpens Piedmont Natural Gas Town of Cowpens (building safety by CC&I Services)
Gaffney Piedmont Natural Gas City of Gaffney Community Development; Cherokee County Building Safety outside city limits
Duncan Greer CPW Town of Duncan
Wellford Greer CPW City of Wellford
Lyman Greer CPW Town of Lyman zoning approval, then CC&I Services
Moore Varies: Piedmont, Greer CPW or propane Spartanburg County Building Codes
Woodruff Piedmont Natural Gas City of Woodruff Building Department
Landrum Greer CPW City of Landrum (start at City Hall); Spartanburg County Building Codes outside city limits
Campobello Mostly propane (no gas main confirmed) Spartanburg County Building Codes (confirm with Campobello Town Hall)
Roebuck Piedmont Natural Gas Spartanburg County Building Codes
Pacolet City of Union (Union Gas) Town of Pacolet, through its contracted building inspection firm
Converse Piedmont Natural Gas Spartanburg County Building Codes
Fairforest Piedmont Natural Gas Spartanburg County Building Codes
Startex Greer CPW or Piedmont (check your bill) Spartanburg County Building Codes
Reidville Greer CPW Town of Reidville (zoning approval, then CC&I for permits); Spartanburg County outside town limits
Arcadia Piedmont Natural Gas Spartanburg County Building Codes
Clifton Piedmont Natural Gas Spartanburg County Building Codes
Drayton Piedmont Natural Gas Spartanburg County Building Codes
Fingerville Propane in most homes; check for Piedmont service Spartanburg County Building Codes
Glendale Piedmont Natural Gas (where mains reach) Spartanburg County Building Codes
Gramling Varies: propane or natural gas, by road Spartanburg County Building Codes
Greer Greer CPW City of Greer Building and Development Standards (inside city limits)
Holly Springs Varies: Greer CPW, Piedmont or propane Spartanburg County Building Codes
Mayo Varies: Piedmont where mains run, propane elsewhere Spartanburg County Building Codes
Pacolet Mills City of Union (Union Gas); confirm on your bill Town of Pacolet, through its contracted building inspection firm
Pauline Varies: Piedmont where mains run, propane elsewhere Spartanburg County Building Codes
Southern Shops Piedmont Natural Gas Spartanburg County Building Codes
Una Piedmont Natural Gas Spartanburg County Building Codes
Whitestone Varies: Piedmont where mains run, propane elsewhere Spartanburg County Building Codes
Chimney Rock Propane (no gas main) Rutherford County Building Inspections (village zoning permit first)
Lake Lure Propane (no gas main) Rutherford County Building Inspections (Town of Lake Lure zoning permit first)
Forest City Enbridge Gas North Carolina Town of Forest City Building Inspections
Rutherfordton Enbridge Gas North Carolina Rutherford County Building Inspections (town zoning permit first for additions)
Spindale Enbridge Gas North Carolina Rutherford County Building Inspections (town zoning permit first for additions)
Union Mills Mostly propane Rutherford County Building Inspections
Mill Spring Enbridge Gas North Carolina (limited); propane elsewhere Polk County Building Inspections
Tryon Enbridge Gas North Carolina Polk County Building Inspections (Town of Tryon zoning permit first)
Columbus Enbridge Gas North Carolina Polk County Building Inspections (Town of Columbus zoning permit first)
Green Creek Mostly propane Polk County Building Inspections

Utility territories have edges, and rural homes past the mains run on propane. Check your bill if you are unsure.

Why homeowners call Gas Guys for gas logs

Gas is the trade we know best

A gas log set is a gas appliance with a valve, a pilot and a safety circuit. We treat it that way, not as a chimney accessory.

We find the actual fault

We test thermocouples, thermopiles and switches with a meter before replacing anything, so you pay for the part that failed.

Straight answers on old sets

If an old set is not worth fixing, we say so, and explain why.

The first cold night is covered

We answer around the clock, including the evening everyone tries their logs for the first time.

Reviews

What customers say about our gas work

5.0 from 131 Google reviews

Jake did a great job of getting my gas powered fireplace back operational. Previously, I was informed from another company’s service technician that I needed to replace the fireplace unit, which would cost thousands of dollars. Jack took care of the problem within a short period of time! Thanks again Jake!!

Eric M. · Google · February 2026

Ethan came out to ensure my gas logs was working properly ahead of an upcoming storm. He was prompt, professional, and very thorough. He checked everything carefully, explained what he was doing, and confirmed the system was operating correctly. I appreciated his honesty and attention to detail and would confidently recommend him for gas and plumbing services. I appreciate Jake and his team for taking care of me.

Lori T. · Google · February 2026

Jake came out to assist my parents in getting their gas logs restarted before the ice storm. He was so helpful and didn’t take but a couple of minutes to get it done. HIGHLY RECOMMEND. My mom and dad were so grateful. So nice, thank you!

K. S. · Google · February 2026

More reviews Read them all on Google

Questions

Gas Logs Sales, Installation & Service: common questions

Still not sure? Call (864) 415-7482. A person answers 24/7. Or browse every common question.

Is it safe to leave gas logs on overnight?

Not as a rule. Vent-free gas logs should never be left burning while you sleep or with nobody in the room; most manufacturers limit how long they should run. Vented logs and sealed direct-vent fireplaces are designed differently, but you should still follow the manual, keep the damper or vent working, and have working carbon monoxide alarms.

My gas fireplace remote stopped working. Is it the logs?

Often it is not. Start with fresh batteries in both the remote and the receiver, which usually sits under the logs or behind a lower panel, and check that the wall switch or receiver is set to remote. If the pilot is lit and the remote still does nothing, the receiver, valve or wiring needs a look.

Why will my gas logs not stay lit?

If the pilot goes out when you release the knob, the thermocouple or thermopile is usually not producing enough voltage, or the pilot flame is too small to heat it because the pilot is dirty. If vent-free logs shut off after running a while, the oxygen depletion sensor may be tripping. Both are testable and fixable.

Why will my gas logs light the pilot but not the burner?

On a millivolt system the thermopile powers the valve and the wall switch. A weak thermopile, a loose or corroded switch wire, or dead batteries in the remote receiver will leave the pilot lit with no burner. We test each piece to find which one it is.

How often should gas logs be serviced?

Once a year before the heating season is a good rule. A cleaning and inspection clears dust and insects from the pilot, confirms the safety controls work and catches leaks or sooting early.

Are vent-free gas logs safe?

They are listed for use when installed and operated by the manufacturer's instructions, including room size and run-time limits, and they have an oxygen depletion sensor that shuts them off if oxygen drops. They do add moisture and combustion products to the room, so a working carbon monoxide alarm is essential and they are not meant for bedrooms or bathrooms.

Can I close the damper when my gas logs are on?

Not with vented logs. Their exhaust goes up the chimney, and the code requires the damper to be fixed open on a vented decorative set. Closing it pushes exhaust, including carbon monoxide, into the room.

Why are my gas logs making soot?

The most common cause is logs out of position, which puts them in the flame. Clogged burner ports, a misadjusted air shutter or the wrong gas type for the burner can also do it. Soot means incomplete combustion, so stop using the set until it is checked.

Can you add gas logs to my wood-burning fireplace?

Yes, if the fireplace and chimney are sound. We run a gas line to the hearth with a shutoff valve, get it permitted and inspected, and install the log set. Have the chimney cleaned first if it has burned wood.

Do you sell gas logs?

Yes. We sell gas log sets and install them, and we help you pick vented or vent-free and a burner sized to your firebox. If the fireplace has no gas line or valve, we run that too, so the whole job is handled by one company.

Do you service gas logs on propane?

Yes. Propane and natural gas sets use different orifices and pressures, so replacement parts must match the gas type on the rating label. A set built for one gas must not be run on the other without the manufacturer's conversion.

24/7 · Spartanburg County & western NC

Need gas logs sales & service?

Call any hour, or send the details and a photo. You get the price before any work starts.

(864) 415-7482
  • Real people answering 24/7
  • Transparent, up-front pricing
  • Fully licensed & insured in SC & NC
  • Locally owned & operated
  • Financing available

Request service

Urgent? Call (864) 415-7482 instead.